MIL-C-5015 스타일 커넥터

MIL-C-5015 style connectors

형상 모델 설명 케이블 종류 CE
6 2 socket, MIL-C-5015, IP50 (protection against dust)
Amphenol, mates w/ 6M connector Kit
Part Number = R6 Solder only (no crimp)
J3, J4, J5A, J6, J9, J9T, J9T2, J9T2A, J10, J51, J61, J81, J93
6D2 2 socket, MIL-C-5015
suitable for Class I Div 2/Zone 2 locations
Must be assembled at factory
J9T2A, J9T2AS, J9T2B, J10, J88C
6GD2 3 socket, MIL-C-5015
suitable for Class I Div 2/Zone 2 locations
Must be assembled at factory
J9T3A, J12
6GQ/6GQI 3 socket, MIL-C-5015, IP68 (indefinite underwater immersion)
high temp 200°C
Viton® B boot
field-installable
Q = electrical contact between shield and transducer housing
QI = electrical isolation between shield and transducer housing
HTC KIT required for field installation Kit part number = R6GQ
J9T3A
6GSL/6GLSI 3 socket, MIL-C-5015, IP67 (submersible to 1 meter)
Viton® B boot
field-installable
SL = electrical contact between shield and transducer housing
SLI = electrical isolation between shield and transducer housing
SPKIT required for field installation
J9T3, J9T3A
6GW Molded, 3 socket, MIL-C-5015, IP67 (submersible to 1 meter)
electrical isolation between the shield and transducer housing
1. Must be assembled at factory
2. Standard lengths available.
Custom length cable assemblies having the 6GW connector must be purchased in quantities of at least 10 pieces per order and are subject to additional lead-time.
J9T3A
6H/6HI 2 socket, MIL-C-5015
HART-compatible
Must be assembled at factory
J3, J9T2A, J9T2AS, J10
6HD2/6HID2 2 socket, MIL-C-5015
HART-compatible
Class I Div 2 suitable
Must be assembled at factory
J9T2A, J10
6M 2 pin MIL-C-5015, IP50 (protection against dust), Amphenol, mates with 6 connector J3, J5A, J9T, J9T2, J9T2A, J9T2AS, J10
6Q/6QI 2 socket, MIL-C-5015, IP68 (indefinite underwater immersion)
high temp 200°C
Viton® B boot
field-installable
Q = electrical contact between shield and transducer housing
QI = electrical isolation between shield and transducer housing
HTC KIT required for field installation Kit part number = R6Q
J5A, J9T, J9T2, J9T2A, J9T2AS, J9T2B, J10, J10S, J51, J61, J88, J88C
6QA/6QAI 2 socket, MIL-C-5015, IP68 (indefinite underwater immersion)
high temp 200°C
Viton® B boot
field-installable
QA = electrical contact between shield and transducer housing
QAI = electrical isolation between shield and transducer housing
HTC KIT required for field installation Kit part number = R6QA
J9F
6SL/6SLI 2-socket, MIL-C-5015, IP67 (submersible to 1 meter)
Viton® B boot
field-installable
Cannot be used with the 780A, 784A, 785A, or 788A sensors.
J5A, J9, J9T, J9T2, J9T2A, J9T2AS, J9T2S, J9T3, J9T3A, J9T4, J10, J51, J81
6W Molded, 2-socket, MIL-C-5015, IP67 (submersible to 1 meter)
electrical isolation between the shield and transducer housing
1. Must be assembled at factory
2. Available for 16, 32, and 64 ft cable lengths only except as indicated in Stocked cable assemblies.
Custom length cable assemblies having 6W connector must be purchased in quantities of at least 10 pieces per order and are subject to add’l cost and/or lead-time.
J5A, J9F, J9T2, J9T2A, J9T2AS, J9T2B, J9T2S, J10
6WP Molded, 2-socket, MIL-C-5015, IP65
electrical isolation between shield and transducer housing
for use in portable/ walkaround applications Must be assembled at factory
J88, J88C
6WR Molded, 2-socket, MIL-C-5015, IP67 (submersible to 1 meter)
electrical isolation between the shield and transducer housing
right angle
1. Must be assembled at factory
2. Available for 16, 32 and 64 ft cable lengths only except as indicated in Stocked cable assemblies.
Custom length cable assemblies having the 6WR connector must be purchased in quantities of at least 10 pieces per order, subject to add’l cost and/or lead-time.
J5A, J9F, J9T2A, J9T2B, J10